Timing
All observation boundaries come from the device's monotonic clock, which has nanosecond resolution, keeps counting while the device sleeps, and ignores time-zone and wall-clock changes. Each study has its own study clock:
Every observation stores its start and end offsets. When you tap the next element, the open one closes and the new one opens at the same offset, so no time is lost or counted twice. Wall-clock timestamps are derived from a single anchor, so they always agree with the measured durations. The on-screen counter reads these timestamps; animation timers never measure time.
| Mode | Behavior |
|---|---|
| Continuous | Tapping an element closes the open one and opens the next at the same instant. The watch reading is cumulative. |
| Snapback | Same boundaries, but the element display resets on each lap. |
| Individual | Tapping an open element stops it. Gaps between elements stay unassigned. |
| Overlap (opt-in) | A tap opens an element alongside any others; tapping it again closes it. |
Pause excludes time from every open element. Interrupt suspends the open element and times the delay element you choose; the delay is excluded from the suspended element. When the app goes to the background, a checkpoint is saved and the time away is recorded as an interruption. Spans over 60 seconds flag open observations for review.
Raw vs derived data
Only raw facts are stored: observation boundaries, timestamps, ratings, quantities, validity and exclusion flags, cycles, interruptions, samples and audit events. Every duration, statistic, normal or standard time is computed on demand and never stored, so analytics, the workbook and backups always agree.
- Valid observations (not scratched) feed time composition: time share by element, category and value class.
- Valid, non-excluded observations feed statistics and labor standards.
Descriptive statistics
For each element, group, cycle, subject and the study as a whole: n, total, mean, median, minimum, maximum, sample standard deviation, coefficient of variation (SD ÷ mean), and the 25th, 75th, 90th and 95th percentiles. Percentiles use linear interpolation, matching Excel's PERCENTILE.INC.
Confidence interval and precision
Intervals use Student's t distribution at the confidence level you set for the study (95% by default in the demo studies):
A study is flagged when an element's relative precision doesn't meet your target (for example ±5%) or when n is too small to estimate it.
Sample size
Two estimates of the number of observations needed for your precision target, labeled separately:
- Preliminary (normal): n = (z × s ÷ (precision × mean))², using the normal distribution.
- Iterative t: the same calculation with t in place of z, repeated until n is stable. Because t depends on n, this estimate is the more conservative one for small studies.
Outliers
Readings are flagged by IQR fences, z-score, or both. Nothing is removed automatically. You review each flag and decide whether to exclude the observation, and the analysis shows the labor standard both with your exclusions and with all valid observations, so the effect of every exclusion is visible.
Normal and standard time
Allowances (for example personal, fatigue and unavoidable delay) are totalled into A. You choose the convention per study:
With a 12% allowance, the first gives a factor of 1.1364 and the second 1.12. The workbook's Productivity & Labor sheet shows both conventions side by side as scenarios. Allowances of 100% or more trigger a warning.
Cycle and per-unit standards
Productivity follows: standard units per hour = 3600 ÷ standard seconds per unit. Observed units per hour (actual output ÷ elapsed time, with no rating or allowance) is reported alongside, together with utilization and cycles per hour.
Labor planning
Example from the demo order-picking workbook: 48.804 s per order line is 0.013557 h. For 10,000 lines a day at 85% planned efficiency, that's 159.5 labor hours, or 19.9 FTE at 8 paid hours per person.
Work sampling
Each activity's proportion p = count ÷ total observations is reported with two intervals: Wald (p ± z√(p(1−p)/n)) and Wilson, which behaves better for small samples and for proportions near 0 or 1. The required sample size for an absolute accuracy target (for example ±5 percentage points) is n = z² p(1−p) ÷ e².
Prompts can be random (stratified across the window), fixed-interval, rapid or manual. A sample is recorded only when you respond. Both scheduled and actual times are stored, and the difference is reported as response delay.
In the workbook
The exported .xlsx recomputes the statistics above with live formulas: counts, means, medians, SDs, CVs, percentiles, t critical values (TINV), confidence intervals, preliminary sample size (NORMSINV), normal and standard times, allowance factors, per-cycle and per-unit standards, productivity, labor hours, headcount, scenarios and KPI tiles. Changing an observation's Valid or Excluded drop-down on Raw Observations recalculates all of them.
A few values are fixed snapshots taken at export, and the Settings & Methodology sheet lists them: the iterative-t sample size, outlier counts, cycles observed, cycle exception counts, Wilson intervals, findings text, which rows appear in the top-consumer and delay tables, and chart caches.
Formulas use only functions available since Excel 2007, are bounded to the actual data rows, and are guarded against #DIV/0! for empty or small studies. Every formula is saved with its calculated value.
Assumptions
The statistics assume observations are independent and the process is stable during the study. These assumptions are documented in the app and in the workbook. If a process is drifting, for example during a learning curve or a shift change, the cycle time trend chart is the place to see it before you trust the mean.